What was found
MAIN CABIN, FLOORBEAM UPPER SURFACE HAS EXFOLIATION CORROSION AT BS 950, BTW LBL 24.75 AND LBL 45.50. REMOVED TEE SECTION OF FLOORBEAM IAW SRM 51-30-2. FABRICATED, LOCATED, AND DRILLED NEW TEE SECTION IAW SRM 51-30-5. INSTALLED TEE SECTION IAW SRM 51-30-2 AND 53-10-2, FIG 7.