What was found
DURING HFEC OPEN HOLE INSPECTION ON RT REINFORCE BASES JUNCTION AT FRAME 52, FOUND 13TH HOLE COUNT FROM TOP WITH CRACK INDICATION. PERFORMED REPAIR IAW EA6-5310-143613, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING HFEC OPEN HOLE INSPECTION ON RT REINFORCE BASES JUNCTION AT FRAME 52, FOUND 13TH HOLE COUNT FROM TOP WITH CRACK INDICATION. PERFORMED REPAIR IAW EA6-5310-143613, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.