What was found
LT WING FIXED L/E AT STATION 467 TELESCOPIC DUCT CUTOUT SKIN SUSPECT CRACKED. REPAIR CARRIED OUT IAW SRM 57-40-01, REPAIR 10, FIG 201, REV 47 AND 51-33-01 AND 51-35-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112. LT NR 3 SLAT REMOVED AND REINSTALLED IAW AMM 27-80-30, REV 70.0. ADJUSTMENT AND TEST CARRIED OUT IAW AMM 27-80-30-5-0, REV 70.0. TELESCOPIC DUCT REMOVED AND REINSTALLED IAW AMM 30-11-01, REV 70.0. LEAK CHECK CARRIED OUT IAW AMM 30-11-01-4, REV 70.0 NO LEAK FOUND.