What was found
RAMP REPORTED DENT 17 IN AFT OF FWD LOWER CARGO DOOR AND APPROX 57 IN UP FROM BOTTOM OF DOOR OPENING. INSP IAW SRM 53-10-12 DIAGRAM 109 WITIN LIMITS OF "B" NO REPAIR REQUIRED. REINSPECT WITHIN 3000 FC. ACFT OK TO CONTINUE. NO RESTRICTION REF: SRM 53-10-12 AFT OF THE FWD CARGO DOOR MX REPORTED A DENT, 17 IN. AFT AND 57 IN ABOVE THE BOTTOM OF THE DOOR OPENING. REF: SRM 53-10-12 INTERMEDIATE ACTION REQUIRED AT OR BEFORE: SPEC: 3,000 CYCLES. EXPIRATION: 21,517 CYCLES, TERMINATING ACTION REQUIRED AT OR BEFORE: NEXT: C-CHECK. DENT FUSELAGE SKIN TRIMMED-OFF BETWEEN FR 26/32 TO FR 33, STR 32R TO 34R IAW SRM 53-10-12, REV 79, FIG 225. HFEC INSP CARRIED OUT IAW NTM 51-10-08, REV 74 FOUND NO CRACKED EVIDENT. REPAIR DOUBLER FABRICATED USING 2024 T3-0.071" AND REPAIR PARTS INSTALLED IAW SRM 53-10-12, REV 79, FIG 225.