What was found
FLOORBEAM TEE BETWEEN RBL 41-62 BS 324 CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-08. ORIGINAL MATERIAL .0125 AFTER REWORK .110. R & R TEE IAW SRM 51-40-01. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM TEE BETWEEN RBL 41-62 BS 324 CORRODED. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-08. ORIGINAL MATERIAL .0125 AFTER REWORK .110. R & R TEE IAW SRM 51-40-01. MAJOR REPAIR.