What was found
LT WING ABOVE NR 1 PYLON OTBD SIDE FIXED L/E FOUND WITH CHAFING MARK. FOUND EXCEEDED LIMIT ORIGINAL THICKNESS = 0.090", MATERIAL REMOVED = 0.033", REMAINED THICKNESS = 0.057, DIAMETER = 0.8" X 8" IAW SRM 57-00-00, FIG 202, REV 47. DAMAGED SKIN REMOVED AND NEW SKIN INSTALLED IAW SRM 51-33-01 AND 51-35-01, REV 47. NEW SKIN FABRICATED IAW DWG ARC 2363. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.