MDCC FRAME 28 HAS 2 GOUGES, .100" BETWEEN STR L17 AND L18. FABRICATED AND INSTALLED 1EA REPAIR PLATE AND 1 EA BRIDGE IAW SRM 51-40-21 AND COMPLIED WITH EA6-5310-145643.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MDCC FRAME 28 HAS 2 GOUGES, .100" BETWEEN STR L17 AND L18. FABRICATED AND INSTALLED 1EA REPAIR PLATE AND 1 EA BRIDGE IAW SRM 51-40-21 AND COMPLIED WITH EA6-5310-145643.