What was found
CABIN AT STA 5-11 TO STA 5-32 X=-108.75 SEAT TRACK BASE FOUND CORRODED. EXCEEDED LIMITS, REMOVED IAW SRM 51-31-01, REV 47 AND SRM 53-00-52, FIG 201, REV 47. CORROSION REMOVED IAW SRM 51-21-01, REV 47, ORIGINAL THICKNESS = 0.104", REMAINED MATERIAL = 0.050" MATERIAL REMOVED = 0.054" FOUND EXCEEDED LIMIT IAW SRM 53-00-52, FIG 101, REV 47. NEW REPAIR SEAT TRACK SECTION AND SPLICE FABRICATED IAW SRM 53-00-52, FIG 201, REV 47. NEW REPAIR SEAT TRACK SECTION AND SPLICE INSTALLED AS IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.