What was found
INNER FUSELAGE INTERCOSTAL IS BENT STR 33L BETWEEN FR85 TO FR84. REMOVED INTERCOSTAL STR 33L BETWEEN FR85 TO FR84 IAW SRM51-40-21, PARA 6, B/S FABRICATED STIFFENER AND WEB IAW DWG A53986749.LOCATED AND DRILLED AND INSTALLED STIFFENER AND WEB ,FR85 TO FR84, STR 33L. REPROTECTED AREA IAW SRM 51-75-10. INSTALLATION SRM 51-40-21, PARA 6 & 7.