What was found
MAIN DECK FRAME STA 1280, RT, BETWEEN S11-12R, DEEP GOUGE IN FRAME FLANGE. REMOVED GOUGE ON FRAME STA 1280 BETWEEN S-11R TO S-12R IAW SRM 51-10-02. ORIGINAL THICKNESS .071, REMAINING THICKNESS .011. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07 FIG 101, DETAIL II. R & R FRAME SECTION IAW SRM 53-00-07, REPAIR 1.