What was found
AFT PIT BS 1110 FRAME, UPPER FLANGE IS PUNCTURED AND CRACKED ABOVE STR 27R. CUT OUT DAMAGE AREA IAW SRM 51-40-2, FIG 1. FABRICATED REPAIR PART IAW SRM 51-40-2, FIG 1. INSTALLED REPAIR DOUBLER IAW SRM 51-40-2, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT PIT BS 1110 FRAME, UPPER FLANGE IS PUNCTURED AND CRACKED ABOVE STR 27R. CUT OUT DAMAGE AREA IAW SRM 51-40-2, FIG 1. FABRICATED REPAIR PART IAW SRM 51-40-2, FIG 1. INSTALLED REPAIR DOUBLER IAW SRM 51-40-2, FIG 1.