What was found
CORRODED FLOORBEAM TOP TEE, BL 0 TO RBL 25, STA 560. CUTOUT DAMAGE AREA, FABRICATED NEW REPAIR AND INSTALLED NEW REPAIR IAW SRM 53-10-8 FIG 3 & SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED FLOORBEAM TOP TEE, BL 0 TO RBL 25, STA 560. CUTOUT DAMAGE AREA, FABRICATED NEW REPAIR AND INSTALLED NEW REPAIR IAW SRM 53-10-8 FIG 3 & SRM 51-30-2.