What was found
UPPER AFT AREA OF AFT CARGO DOOR CUTOUT, EXT SURFACE, HAS MULTIPLE SCRATCHES EXTENDING 10" AFT OF CUTOUT (FR63) BETWEEN STRINGERS 27R & 28R. SMOOTHED AND BLENDED 10" SQ IN AFT CARGO DOOR CUTOUT EXT SURFACE FR63, STR 27 & 28 IAW SRM 51-73-10. MAP AREA FOR NDT REMAINING THICKNESS . FOUND WITHIN ALLOWABLE L/E LIMIT .079 MATL LOSS .012 AND .009. R & R 3 EA HILOKS IAW SRM 53-17-12, FIG 103, PG 119-120. REPROTECTED AREA IAW A51-75-10. ORG THICKNESS .236 & .158, FIG 2, PAGE 11, REMAIN THICKNESS .224 & .149.