What was found
CENTER CARGO COMPARTMENT ALONG STA 1841, BETWEEN LONGERON 45L AND LONGERON 48R, FLOORBEAM WEB AREAS FOUND SURFACE CORROSION. CORROSION REMOVED IAW SRM 51-21-01, REV 47. FOUND EXCEEDED LIMIT IAW SRM 53-00-00, FIG 202, REV 47. R & R IAW SRM 51-35-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.