What was found
ONE CRACK INDICATION EXCEEDS 25 PERCENT FSH WAS FOUND AT NR 63 FASTENER HOLE OF RT CENTER WING, REF NTM PART 6 51-10-01 PROCEDURE A RECORD SHEET FIG 611 AND NTM PART 6-57-10-12. CRACK REAMED TO THE NEXT NOMINAL DIAMETER 0.561" IAW EO 6-5710-7-3322 PART 1. NDI COMPLETED, NO CRACK INDICATION FOUND IAW EO 6-5710-7-3322 PART 1. INSTALLED NEW FASTENERS IAW EO 6-5710-7-3322 PART 1. THE REPAIR EVALUATED PER G.M.M. 6-2-100 AND CLASSIFIED AS MAJOR.