What was found
STRINGER SPLICE CORRODED, BS 480, STR 28R. REMOVED DAMAGED STRINGER SPLICE. FABRICATED NEW SPLICE, AND INSTALLED IAW SRM 51-30-2 & DWG 69-14492.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STRINGER SPLICE CORRODED, BS 480, STR 28R. REMOVED DAMAGED STRINGER SPLICE. FABRICATED NEW SPLICE, AND INSTALLED IAW SRM 51-30-2 & DWG 69-14492.