What was found
CORROSION ON FS 740, FITTING & ITS ASSOCIATED HARDWARE ON RT SIDE AT KEELBEAM INSIDE RT ACFT BAY. ALSO, AREAS OF CORROSION ON FUSELAGE CIRCUMFERENCE IN SAME VICINITY. REMOVED DAMAGED SUPPORT FITTING, FABRICATED & INSTALLED NEW SUPPORT FITTING AT BS 740, RT SIDE IAW DWG 69-64841, SRM 51-30-5, & SRM 51-30-2.