What was found
CORROSION ON TOP FLOORBEAM TEE, BS 720D, BL 0 TO RBL 12. CUTOUT DAMAGE AREA, FABRICATED REPAIR & INSTALLED REPAIR IAW SRM 53-10-8, FIG 3 & SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON TOP FLOORBEAM TEE, BS 720D, BL 0 TO RBL 12. CUTOUT DAMAGE AREA, FABRICATED REPAIR & INSTALLED REPAIR IAW SRM 53-10-8, FIG 3 & SRM 51-30-2.