What was found
CORRODED TOP TEE FLOORBEAM BS 680 BETWEEN RBL 25 TO RBL 45. CUTOUT DAMAGE, FABRICATED REPAIR & INSTALLED IAW SRM 53-10-8 FIG 3 & SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED TOP TEE FLOORBEAM BS 680 BETWEEN RBL 25 TO RBL 45. CUTOUT DAMAGE, FABRICATED REPAIR & INSTALLED IAW SRM 53-10-8 FIG 3 & SRM 51-30-2.