What was found
RT FUSELAGE BENEATH AFT BODY FAIRING (LOWER SIDE) FROM STA 2155 TO 2164 FOUND CORRODED AT SEVERAL LOCATIONS. CORROSION REMOVED, ORIGINAL THICKNESS 0.095", MATERIAL REMOVED 0.045", REMAINING THICKNESS 0.050". REPAIR CARRIED OUT IAW SRM 53-70-01, FIG 201, REPAIR 3, REV 47. MAJOR IAW GMM 6-2-100, REV 112.