What was found
SEAT TRACK AT MAIN DECK STA 1831 TO 1887, X = 8.5 LT, FLANGE FOUND CORRODED, CORROSION REMOVED, ORIGINAL THICKNESS = 0.080 INCH; MATERIAL REMOVED = 0.040"; MATERIAL REMAINED = 0.040 INCH AND EXCEEDED LIMITS IAW SRM 53-00-52, REV 47, FIG 101. NEW SEAT TRACK REPAIR CARRIED OUT IAW SRM 53-00-52 REV 47, FIG 201 REPAIR 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.