What was found
SEAT TRACK AT MAIN DECK STA 1229 TO 1331, X = 27.5 LT, FOUND WITH CORROSION THAT EXCEEDED SRM LIMITS. CORRODED AREA REMOVED: MATERIAL THICKNESS = 0.0890 INCH, MATERIAL REMOVED = 0.040", MATERIAL REMAINED = 0.040". EXCEEDED LIMITS IAW SRM 53-02-52, REV 47, FIG 101. REPAIR CARRIED OUT IAW SRM 53-00-52, REV 47, FIG 201, REPAIR 1. ACCOMPLISHED EO 1-5100-7-5001, REV A5, PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.