What was found
FLOORBEAM LOWER FLANGE IS CORRODED AT BS 1070 BTWN BL 0 - RBL 24. FABRICATED AND INSTALLED REPAIR ANGLES AND FILLER IAW SRM 53-10-8 FIG 8 REV. 103.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM LOWER FLANGE IS CORRODED AT BS 1070 BTWN BL 0 - RBL 24. FABRICATED AND INSTALLED REPAIR ANGLES AND FILLER IAW SRM 53-10-8 FIG 8 REV. 103.