What was found
CORROSION ON SEAT TRACK FLANGE AT STA 1761 TO 1821, X = -8. CORROSION REMOVED IAW SRM 51-21-01, REV 47. ORIGINAL THICKNESS=0.080"; MATERIAL REMOVED=0.045"; MATERIAL REMAINED=0.035 INCH, FOUND EXCEEDED SRM 53-00-52, REV 47, FIG 101 LIMITS. CORRODED SECTION REMOVED IAW SRM 51-31-01, REV 47. REPAIR FABRICATED IAW SRM 53-00-52, REV 47, FIG 201, REPAIR 1 AND INSTALLED IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.