What was found
CORROSION ON SEAT TRACK FLANGE AT STA 1461 TO 5.0, X = 107. CORROSION REMOVED IAW SRM 51-21-01, REV 47. ORIGINAL THICKNESS=0.080 INCH; MATERIAL REMOVED=0.050 INCH; MATERIAL REMAINED =0.030 INCH, FOUND EXCEEDED SRM 53-00-52, REV 47, FIG 101 LIMITS. CORRODED SECTION REMOVED IAW SRM 51-31-01, REV 47. REPAIR FABRICATED IAW SRM 53-00-52, REV 47, FIGURE 201, REPAIR 1 AND INSTALLED IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.