What was found
AFT PIT 1540 FRAME LT AT STR 26L FRAME FLANGE GOUGED AND DENTED. BLENDED OUT GOUGED AREA IAW SRM 51-10-02. ORIGINAL MATAERIAL THICKNESS. .071, REMAINING MATERIAL .066. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-07, FIG 101, DETAIL AD2. R & R FRAME IAW SRM 51-40-02. MAJOR REPAIR.