What was found
RT WING FIX L/E IS GOUGED APPROX 6" LONG BETWEEN SLAT TRACK 5 AND 6, FROM CONTACT WITH NR 2 SLAT LOWER SKIN FASTENERS. SMOOTHED AND BLENDED AREA IAW SRM 51-75-10 AT RT WING FIX L/E SLAT TRACK 5 AND 6. NDT FOR CRACK AND LIMITS, NO LIMIT REMAINING THICKNESS. CUTOUT DAMAGE AREA FOR REPAIR IAW SRM 57041-12PB201, FIG 204. FORMED AND FAB NEW SKIN SECTION, FABRICATED 2EA BUTT STRAPS AND 2EA REINFORCING STRAPS,IAW SRM57-41-12 FIG 204, DRILLED AND INSTALLED REPAIR PARTS IAW SRM 57-41-12. REPROTECTED AREA IAW SRM 51-75-10.