What was found
FWD PIT, FRAME SHEAR TIE CORRODED AT BS 660, BETWEEN S28L-R. REMOVED & FABRICATED SHEAR TIE IAW SRM 53-10-4 FIG 15 AND INSTALLED IAW SRM 51-30-2 REV 103.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT, FRAME SHEAR TIE CORRODED AT BS 660, BETWEEN S28L-R. REMOVED & FABRICATED SHEAR TIE IAW SRM 53-10-4 FIG 15 AND INSTALLED IAW SRM 51-30-2 REV 103.