What was found
FLOOR SUPPORT AT RT STA 595, X = -75.25 CORRODED BEYOND SRM LIMITS. CORROSION REMOVED IAW SRM 51-21-01, REV 47. MATERIAL ORIGINAL THICKNESS = 0.075"; MATERIAL REMOVED = 0.050"; MATERIAL REMAINED = 0.025" FOUND EXCEEDED LIMIT IAW SRM 53-00-00, REV 47, FIG 202. ACCOMPLISHED EA 1-5310-154215. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.