What was found
CORRODED TOP FLOORBEAM TEE BS 620 BL 0-RBL 25. CUTOUT DAMAGED AREA, FABRICATED REPAIR, TEE, SUPPORT ANGLES AND REINFORCEMENT STRAPS IAW SRM 53-10-8 FIG 3, INSTALLED FLOORBEAM REPAIR IAW SRM 53-10-8 FIG 3 AND SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORRODED TOP FLOORBEAM TEE BS 620 BL 0-RBL 25. CUTOUT DAMAGED AREA, FABRICATED REPAIR, TEE, SUPPORT ANGLES AND REINFORCEMENT STRAPS IAW SRM 53-10-8 FIG 3, INSTALLED FLOORBEAM REPAIR IAW SRM 53-10-8 FIG 3 AND SRM 51-30-2.