What was found
VERTICAL ANGLE CORRODED ABOVE S26R, BS 740. REMOVED VERTICAL ANGLE IAW SRM 51-30-02. CUTOUT DAMAGE DIM: 2" X 3" AND FABRICATED REPAIR ANGLES & STRAPS IAW SRM 51-40-4 FIG 1. INSTALLED REPAIR PARTS IAW SRM 51-30-02 & SRM 51-40-4 FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
VERTICAL ANGLE CORRODED ABOVE S26R, BS 740. REMOVED VERTICAL ANGLE IAW SRM 51-30-02. CUTOUT DAMAGE DIM: 2" X 3" AND FABRICATED REPAIR ANGLES & STRAPS IAW SRM 51-40-4 FIG 1. INSTALLED REPAIR PARTS IAW SRM 51-30-02 & SRM 51-40-4 FIG 1.