What was found
HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSP CARRIED OUT AND FOUND HOLE ITEM 29 ON RT WING REAR SPAR, NEAR RIB 1 WITH CRACK INDICATION. RT WING REAR SPAR CRACKED FASTENER HOLE REAMED TO DIAMETER 0.560 INCH IAW EO 6-5710-7-3322, PART 1, WORK STEP 4G. HIGH FREQUENCY EDDY CURRENT OPEN HOLE INSPECTION CARRIED OUT IAW NTM REV 74, PART 6. 57-10-12 NO CRACK AND NO DAMAGE FOUND ON REWORKED HOLE. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100, REV 112.