HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AT LT CENTER TANK REAR SPAR AND FOUND DAMAGED AT APPROX 6 O`CLOCK. REPAIRED IAW EO 6-5710-7-3322B1 PT 1. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100 REV112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HIGH FREQUENCY EDDY CURRENT INSPECTION CARRIED OUT AT LT CENTER TANK REAR SPAR AND FOUND DAMAGED AT APPROX 6 O`CLOCK. REPAIRED IAW EO 6-5710-7-3322B1 PT 1. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100 REV112.