What was found
MAIN DECK - CORROSION ON SEAT TRACK FLANGE AT STA 5-0 TO STA 5-53, X =75. CORROSION REMOVED IAW SRM 51-21-01, REV 47. ORIGINAL THICKNESS =0.080"; MATERIAL REMOVED =0.040"; MATERIAL REMAINED = 0.040", FOUND EXCEEDED SRM 53-00-52, REV 47, FIG 101 LIMITS. CORRODED SECTION REMOVED IAW SRM 51-31-01, REV 47. REPAIR FABRICATED IAW SRM 53-00-52, REV 47, FIG 201. REPAIR 1 AND INSTALLED IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 112.