What was found
FWD END OF UPPER KEELBEAM BREATHER WEB AT FS 740 CORRODED COMPLETELY THROUGH WEB, WITH SEVERAL MORE AREAS OF SEVERE CORROSION IN SAME VICINITY. REMOVED DAMAGED KEEL BEAM STIFFNER PLATE, LOCATED DRILLED & INSTALLED NEW STIFFNER PLATE IAW SRM 51-30-5, SRM 51-10-2, & SRM 51-30-2, AND DWG 65-23555.