What was found
LOWER FWD CARGO BAY, LONGERON 52 BETWEEN STA 1119-6-10, FOUND SPLICE FITTING WITH CORROSION. SPLICE FITTING REMOVED AND REPLACED WITH NEW MACHINED SPLICE AS PER SRM 51-33-01 REV 47. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 112.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER FWD CARGO BAY, LONGERON 52 BETWEEN STA 1119-6-10, FOUND SPLICE FITTING WITH CORROSION. SPLICE FITTING REMOVED AND REPLACED WITH NEW MACHINED SPLICE AS PER SRM 51-33-01 REV 47. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 112.