As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BULK CARGO COMPARTMENT 161GF FLOOR PANEL EDGE AREA GOT IMPACT DAMAGED. MEASURED THE DAMAGED AREA IS 15 1/2"X DIA. IS NOT WITHIN THE ALLOWABLE DAMAGED LIMITS. FABRICATED A NEW FLOOR PANEL WITH THE EDGE FILLER, INSERTS AND ADHESIVE IAW SRM 53-10-20, AND DWG 17A53279963. THE REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.