What was found
BULK CARGO COMP'T 161AF FLOOR PANEL EDGE AREA GOT IMPACT DAMAGED. MEASURED THE DAMAGED AREA IS 17" LONG IS OUT OF THE ALLOWABLE DAMAGE LIMITS. FABRICATED A NEW PANEL WITH EDGE FILLER, INSERTS AND ADHESIVE IAW SRM 53-10-20, AND DWG 17A53279966. THE REPAIR CLASSIFIED AS MINOR PER GMM 6-2-100.