What was found
CENTER ACCESSORY COMPARTMENT, BETWEEN STA 6-90 TO STA 1159, LONGERON 47 RT, FOUND CORRODED. CORRSION REMOVED IAW SRM 51-21-01, REV 47. ORIGINAL MATERIAL THICKNESS = 0.090"; MATERIAL REMOVED = 0.049 INCH, FOUND EXCEEDED LIMIT IAW SRM 53-00-00, REV 47, FIG 205. LONGERON REMOVED AND NEW LONGERON INSTALLED IAW SRM 51-31-01, REV 47. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.