What was found
MAIN DECK ZONE 230 FLOORBOARD 231VG HAS DAMAGE AND HAS 1EA SCREEN DRILLED OFF. REF AMM 53-10-20-06-02, FABRICATED REPLACEMENT FLOORBOARD 231VG IAW DWG SRZ-25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK ZONE 230 FLOORBOARD 231VG HAS DAMAGE AND HAS 1EA SCREEN DRILLED OFF. REF AMM 53-10-20-06-02, FABRICATED REPLACEMENT FLOORBOARD 231VG IAW DWG SRZ-25-005, REV J. MAJOR REPAIR IAW GMM 6-2-100.