What was found
RT WING, INBD FLAP, MOST INBD NR 2 HINGE AREA HAS REAR SPAR CHORD CRACKED AT CUT-OUT. CUT OUT DAMAGED SECTION OF SPAR IAW SRM 51-40-4 FIG 3. FABRICATED NEW SPAR SECTION AND SPLICE IAW SRM 51-40-4 FIG 3 AND 57-50-2 FIGURE 5. TREATED, PRIMED AND INSTALLED NEW SPAR SECTION AND SPLICE ANGLE IAW SRM 51-30-2, 51-40-4 FIGURE 3, AND EA 7-5750-152462.