What was found
FLOORBEAM WEB CORRODED BS 880, LBL 45 TO LBL 62. REMOVED CORROSION IAW SRM 51-10-6. NDT INSPECTED AFFECTED AREA IAW EA 7-5310-152465. TREATED AND PRIMED AFFECTED AREA IAW SRM 51-10-2, AND EA 7-5310-152465.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.