What was found
L3 DOOR, AFT SIDE NR 2 (FROM TOP) DOOR STOP FITTING FOUND CRACKED. STOP FITTING REMOVED AS PER SRM 51-31-01 REV 47. INSTALLED AS PER SRM 51- 31-01 REV 47. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REV 113.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
L3 DOOR, AFT SIDE NR 2 (FROM TOP) DOOR STOP FITTING FOUND CRACKED. STOP FITTING REMOVED AS PER SRM 51-31-01 REV 47. INSTALLED AS PER SRM 51- 31-01 REV 47. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REV 113.