What was found
L4 DOOR LOWER GATE OTBD FWD AND AFT CORNERS GOUGED. REMOVED DAMAGE AND CHECKED LIMITS OF DAMAGE IAW SRM 52-10-02, SRM 51-10-02. OUT OF LIMITS FOR DAMAGE IAW SRM 52-10-02, FIG 101, DETAIL V. R & R L4 DOOR LOWER GATE AND OPS CHECKED IAW AMM 52-11-38, AMM 52-11-01, AMM 52-11-00. OPS CHECKED/ADJUSTED GOOD. ORIG MATERIAL .160 AFTER REWORK .108 DEPTH .052. MAJOR REPAIR.