What was found
FLOORBEAM BS 1640, BL15L-R CORRODED. REMOVED AND REPLACED FLOORBEAM PER SRM 53-60-51, AND DRAWING 146N5180. FOUND TO BE CORRODED OUT OF LIMITS PER SRM 53-00-51, FIG.101, DETAIL 3, PAGE 103. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM BS 1640, BL15L-R CORRODED. REMOVED AND REPLACED FLOORBEAM PER SRM 53-60-51, AND DRAWING 146N5180. FOUND TO BE CORRODED OUT OF LIMITS PER SRM 53-00-51, FIG.101, DETAIL 3, PAGE 103. MAJOR REPAIR.