What was found
CRACK FOUND DURING X-RAY INSPECTION AT BS 5-123, LONGERON SPLICE -2L , CRACK LENGTH APPROX 1 INCH. R & R LONGERON SPLICE IAW SRM 51-31-01 REV 47. SPLICE FABRICATED IAW DWG ASA7111, REV C. REPAIR CLASSIFIED MAJOR GMM 6-2-100, REV 113.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK FOUND DURING X-RAY INSPECTION AT BS 5-123, LONGERON SPLICE -2L , CRACK LENGTH APPROX 1 INCH. R & R LONGERON SPLICE IAW SRM 51-31-01 REV 47. SPLICE FABRICATED IAW DWG ASA7111, REV C. REPAIR CLASSIFIED MAJOR GMM 6-2-100, REV 113.