What was found
FLOORBOARD, 241DF HAS 2 EA BROKEN CORNERS AROUND CLEVIS ADAPTER CUT-OUT DEFECT MEASURES 6 INCHES TOTAL FABRICATED REPLACEMENT PANEL 241DF IAW DWG SRZ 25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBOARD, 241DF HAS 2 EA BROKEN CORNERS AROUND CLEVIS ADAPTER CUT-OUT DEFECT MEASURES 6 INCHES TOTAL FABRICATED REPLACEMENT PANEL 241DF IAW DWG SRZ 25-005, REV J, MAJOR REPAIR IAW GMM 6-2-100.