What was found
RT CREASE BEAM GOUGED AT STA 405. BLENDED GOUGE CHECKED LIMITS IAW SRM 53-00-51. MATERIAL REMOVED EXCEEDS 10 PERCENT, .040 REMAINING. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-51, DRAWING III. REMOVED CREASE BEAM IAW 51-40-02 FABRICATED NEW CREASE BEAM IAW SRM 53-10-13 DWG 141N8422. INSTALLED NEW CREASE BEAM STA 405, RBL 62 IAW SRM 51-40-02. MAJOR REPAIR.