What was found
LWR FUSELAGE SKIN FR57.3-58 S44-45R FOUND A DENT 6" IN LENGTH. PERFORMED A DVI AND ENSURED THE DENT IS IN SMOOTH CONTOUR WITHOUT SHARP EDGE. THE SCRATCH HAD BEEN REWORKED TO SMOOTH CONTOUR IAW SRM 51-73-10. PERFORMED A ROTO TEST INSPECTION OF OPENED FASTENER HOLES TO CONFIRM NO DAMAGE. PERFORMED DV AND HFEC INSP FROM INSIDE TO CONFORM NO DAMAGE ON INNER STRUCTURE PARTS. PERFORMED FLAP PEENING ON REWORKED AREA WITH I=0.15MM IAW SRM 51-29-11. PERFORMED SURFACE PROTECTION IAW SRM 51-75-10. INSTALLED 1ST OVERSIZED FASTENERS IAW SRM 51-40-21 COMPLIED WITH EA 6-5330-153460.