What was found
LEFT INBD FLAP, 5 INCHES FROM INBD EDGE FOUND LOWER SURFACE DRAIN HOLE ELONGATED. CARRIED OUT REPAIR IAW EA NR 6- 5750-155851, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEFT INBD FLAP, 5 INCHES FROM INBD EDGE FOUND LOWER SURFACE DRAIN HOLE ELONGATED. CARRIED OUT REPAIR IAW EA NR 6- 5750-155851, REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 113.